TECHNICAL & SERVICE MANUAL
Air-Conditioners For Building Application
<Indoor unit>
2005
Models
Ceiling Cassettes
Series PLFY
PLFY-P06NLMU-E
PLFY-P08NLMU-E
PLFY-P12NLMU-E
PLFY-P15NLMU-E
PLFY-P18NLMU-E
INDOOR UNIT
CONTENTS
SAFETY PRECAUTIONS ·························1
1. FEATURES ···········································3
2. PART NAMES AND FUNCTIONS ········4
3. SPECIFICATION ···································6
4. OUTLINES AND DIMENSIONS············8
5. WIRING DIAGRAM ·····························10
6.
REFRIGERANT SYSTEM DIAGRAM
11····
7. TROUBLE SHOOTING·······················12
8. DISASSEMBLY PROCEDURE···········
17
For use with the R410A & R22
Vista de pagina 0
1 2 3 4 5 6 ... 25 26

Indice de contenidos

Pagina 1 - PLFY-P18NLMU-E

TECHNICAL & SERVICE MANUALAir-Conditioners For Building Application<Indoor unit>2005ModelsCeiling CassettesSeries PLFYPLFY-P06NLMU-EPLFY-P08

Pagina 2 - SAFETY PRECAUTIONS

9PLFY-P06·08·12·15·18NLMU-E with OA duct flangeUnit :mm(in.)52(2-1/16)34(1-11/32)(6-9/32)110(4-11/32)159E20(13-16)(13-16)(13-16)(13-16)(13-16)221(8-23

Pagina 3 - R410A refrigerant

105WIRING DIAGRAMPLFY-P06·08·12·15·18NLMU-ETERMINAL BOXCONTROL BOXCI.B.TB2TB5,TB15PARTS LOCATIONCN22CN24CN25INSIDE SECTION OF TERMINAL BOXFor test of

Pagina 4 - Series PLFY

REFRIGERANT SYSTEM DIAGRAM6Strainer (#100mesh)Strainer (#100mesh)Heat exchangerRoom temparature thermistor TH21Gas pipe thermistor TH23Liquid pipe the

Pagina 5 - PART NAMES AND FUNCTIONS

7TROUBLE SHOOTING7-1. Simple check of main componentsCheck pointsMeasure the resistance between the terminals using a tester.(Surrounding temperature:

Pagina 6 - [Display]

01020304050-20 -10 0 10 20 30 40 50 (˚C)-4 14 32 50 68 86 104 122 [˚F]< Thermistor for lower temperature >TemperatureResistance (KΩ )4ø4365ø32

Pagina 7 - SPECIFICATION

Output(Phase)Outputø11ONø2 ONø3 OFFø4 OFF2OFFONONOFF3OFFOFFONON4ONOFFOFFON<Output pulse signal and the valve operation>➁Linear expansion valve o

Pagina 8

157-2. FUNCTION OF DIP-SWITCH123456789101~6123123412345678910Thermistor<Intake temperaturedetection>positionON OFFFilter crogging detection Prov

Pagina 9 - OUTLINES AND DIMENSIONS

160594837261SW12100594837261SW11108F7E6D5C4B3A291SW140594837261SW120594837261SW1108F7E6D5C4B3A291SW14Operation by switchSwitch Pole Remarks<At deli

Pagina 10 - TENTATIVE

178DISASSEMBLY PROCEDURE8-1.SERVICE PANEL and FILTEROPERATING PROCEDURE1. Removing the service panel (A) (Fig.1-1)(1) Slide the service panel (A) in t

Pagina 11 - WIRING DIAGRAM

188-2.CONTROL BOXOPERATING PROCEDURE1. Remove the service panel and filter with the pro-cedure explained in section 8-1.2. Removing the control box co

Pagina 12 - REFRIGERANT SYSTEM DIAGRAM6

SAFETY PRECAUTIONSand install the unit at the specified place.- Improper installation may cause the unit to topple and result ininjury.• Always use an

Pagina 13 - TROUBLE SHOOTING

198-3.Fan and fan motorOPERATING PROCEDURE1. Remove the service panel and filter with the pro-cedure explained in section 8-1.2. Remove the two screws

Pagina 14 - Linear expansion valve

208-4.Thermistor <fluid piping temperature detection, gas piping temperature detection>OPERATING PROCEDURE1. Remove the service panel and filter

Pagina 15

218-5.DRAIN PUMP and DRAIN SENSOROPERATING PROCEDURE1. Remove the service panel and filter with the pro-cedure explained in section 8-1.2. Remove the

Pagina 16

228-6.LEV and HEAT EXCHANGEROPERATING PROCEDURE1. Remove the service panel and filter with the pro-cedure explained in section 8-1.2. Remove the decor

Pagina 17 - Set while the unit is off

238-7.Vane motorOPERATING PROCEDURE1. Remove the metal cover. (Three screws)(Photograph 8-1)2. Remove the vane motor cover.The vane motor cover can be

Pagina 18 - DISASSEMBLY PROCEDURE

Issued in Aug. 2005 HWE05110New publication, effective Aug. 2005Specifications subject to change without notice

Pagina 19 - (A) Control box cover

3400 Lawrenceville Suwanee Road ● Suwanee, Georgia 30024 Toll Free: 800-433-4822 ● Toll Free Fax: 800-889-9904 www.mrslim.com Specifications ar

Pagina 20 - (A) Bell-mouth

2. Precautions for devices that useCaution:• Do not use the existing refrigerant piping.- The old refrigerant and refrigerator oil in the existing pip

Pagina 21 - 8-4.Thermistor

PLFY-P06NLMU-EPLFY-P08NLMU-EPLFY-P12NLMU-EPLFY-P15NLMU-EPLFY-P18NLMU-E1.8 / 2.02.3 / 2.63.5 / 4.04.4 / 5.05.3 / 5.96000 / 67008000 / 900012000 / 13500

Pagina 22 - (Photo.6-1)

PART NAMES AND FUNCTIONS2● Indoor (Main) UnitAir inletSucks the ambient air in.Long-life filterRemoves the sucked-in dust and dirt.Since the long-life

Pagina 23 - 8-6.LEV and HEAT EXCHANGER

[Display]CCON/OFF CENTRALLY CONTROLLEDERROR CODECLOCKON OFFCHECKCHECK MODEFILTERTEST RUNFUNCTION1Hr.NOT AVAILABLESTAND BY DEFROSTTEMP.ABCEPMFKDOLGNIHJ

Pagina 24 - 8-7.Vane motor

3SPECIFICATION3-1. Specification6Notes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling: In

Pagina 25 - Issued in Aug. 2005 HWE05110

3-2. Electrical parts specificationsø7

Pagina 26 - ● Suwanee, Georgia 30024

4OUTLINES AND DIMENSIONSPLFY-P06·08·12·15·18NLMU-EUnit :mm(in.)83Drain hose2Liquid pipe <flare>1Gas pipe <flare>mm(in.) Fresh air intake