Pagina 1 - City Multi Product Catalogue

CM14AN-C-NZCity Multi Product Catalogue

Pagina 2 - Contents

Comparison of COP (energy efficiency) – 8HP systemThe Difference between YLM-A and Previous Mitsubishi Electric ModelsTechnology is the key when incre

Pagina 3 - Our Latest Technologies

P20P15Capacity P25 P32 P40 P50VBMVHMVKMP63 P100Capacity rangePKFY-P VBM-EPKFY-P VHM-EPKFY-P VKM-EINDOOR UNITWall Mounted TypeElegant design and compac

Pagina 4 - The New EP-YKB/EP-YLM Series

SpecificationsNotes: *1 Cooling/heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor : 27°C(81°F)

Pagina 5

INDOOR UNIT Wall mounted typeMSZ-EF Designer Seriesand PAC-LV11M-J External LEV Kit*An exceptional combination of energy efficiency and award winning

Pagina 6 - VRF Systems

CITY MULTI External LEV Kit for Designer Series High WallsPAC-LV11M-JFeature• Connection between CITY MULTI and Designer Series high walls- Wider

Pagina 7

PFFY-P VKM-E2INDOOR UNITFloor consoleFor living rooms, bedrooms, or offices where a sophisticated designis required. The latest Mitsubishi Electric in

Pagina 8 - Unbeatable Efficiency

SpecificationsNotes: Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB, Outdoor : 35°C(95°F)DB Heating Indoor : 20°C(68°F)DB, Outdoor : 7°C(45°F)DB/

Pagina 9

Compact unit for easy air conditioning in perimeter zone.PFFY-P VLEM-EINDOOR UNITFloor standing exposedStandardized design with mild lines.Supports va

Pagina 10 - Total Energy Conservation

SpecificationsNotes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor : 27°C(81°F)

Pagina 11

Neatly installed with pericover concealed.Easy installation in perimeter zone.PFFY-P VLRM-EPFFY-P VLRMM-EINDOOR UNITFloor mounted concealed typeThe bo

Pagina 12 - Efficient R410A Refrigerant

SpecificationsNotes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor : 27°C(81°F)

Pagina 13

Comparison of COP (energy efficiency) – 8HP systemThe Difference between YLM-A and Previous Mitsubishi Electric ModelsTechnology is the key when incre

Pagina 14 - U nique Technology

CMB-P-V-G1CMB-P-V-GA1CMB-P-V-HA1CMB-P-V-GB1CMB-P-V-HB1BC CONTROLLERIn many ways, the BC Controller is the technological heart of the CITY MULTI R2/WR2

Pagina 15

Specifications43 48 55 62 691-phase 220/230/240V 50Hz/60Hz2891,11052080.127/0.144/0.1610.060/0.068/0.0760.102/0.115/0.1270.048/0.054/0.0600.58/0.63/0

Pagina 16 - “2-pipe” System Provides

Air to Water advanced system explainedAir To Water (ATW) series offers the choice between two types of units; a Booster unit and a HEX (Heat Exchanger

Pagina 17

BOOSTER UNITBenefiting from the heat recovery operation of the CITY MULTI R2 system, Booster unit converts energy from the air to higher temperatures

Pagina 18 - E nergy Saving Technology

HEX UNITPWFY-P100VM-E1-AUPWFY-P200VM-E1-AUBy utilizing waste heat from the R2 outdoor unit for heating operation in HEX unit, it is possible to supply

Pagina 19

SYSTEM OUTLINE HEX unit with Y seriesTank(field supply)Fan coilMachine coolingHEX unitY outdoor unitOUTSIDE MACHINE ROOM INDOORIndoor unitHEX unit is

Pagina 20 - Fit Out Flexibility

Notes:PWFY-P100VM-E-BUPower inputCurrent inputOutdoor unit/Heat source unit conditionBooster unit inlet water temp.Total capacityModel / QuantityLiqui

Pagina 21 - O utdoor Unit

PWFY-P100VM-E1-AUPower inputCurrent inputPower inputCurrent inputOutdoor unit/Heat source unit conditionHEX unit inlet water temp.Total capacityModel

Pagina 22 - Model name

ON / OFFOperation mode switchingWater temperature settingPreset temperature range limitWater temperature displayPermit / Prohibit local operation Erro

Pagina 23

119Indoor Unit

Pagina 24 - Cooling or Heating

For the EnvironmentHistory of RefrigerantR22, an HCFC-based refrigerant, had been a popular choice for most chillers. However, R22 has been targeted b

Pagina 25 - R2 (Heat Recovery) series

The secret to the unmatched comfort provided by Lossnay core is the cross-flow, plate-fin structure of the heat-exchange unit. A diaphragm made of a s

Pagina 26

• Two paths ventilation LOSSNAY simultaneously intakes Fresh Air and exhausts Dirty Air. • Total energy recoverLOSSNAY returns BOTH sensible heat and

Pagina 27 - Expanded to -25°C

ADVANTAGESClean air supply, dirty air exhaust by Two air paths (OA SA and RA EA)Energy recovery by LOSSNAY CoreFree cooling by bypass dampe

Pagina 28 - High Static Pressure Setting

In addition to the conventional Extra High, High, and Low modes, an Extra Low mode is added to provide a more dynamic range of air volume settings and

Pagina 29 - Startup Comfort

In addition to the automatic damper open/close function, open/close control via external devices is now possible, delivering a “By-pass” ventilation s

Pagina 30

Model line up SpecificationLGH-15RX5-ELOSSNAY ventilation By-pass ventilationExtra High High Low Extra Low0.44-0.4696-1101504210.2-10.7100-10582.075

Pagina 31 - (PUHY/PURY-EP-Y(S)LM-A only)

Ventilation modeFan speedCurrent (A) Power consumption (W) Air volumeModelExternal static pressure Temperature exchange efficiency (%)Enthalpy exchang

Pagina 32 - Outdoor Unit

Ventilation modeFan speedCurrent (A) Power consumption (W) Air volumeModelExternal static pressure Temperature exchange efficiency (%)Enthalpy exchang

Pagina 33

ControlThe New Remote Controller PZ-60DR-E enables simple control settingCentralized Controller SystemLOSSNAY independentInterlocked with Air conditio

Pagina 34 - Water Cooled Series

Air Handling Unit ControllerPAC-AH-M-JThe Air Handling Unit Controller is an interface to allow connection to third party manufacturers equipment.Mits

Pagina 35 - [131ft]

For the EnvironmentHistory of RefrigerantR22, an HCFC-based refrigerant, had been a popular choice for most chillers. However, R22 has been targeted b

Pagina 36 - PUMY-P VKM-A(-BS)

Along with Lossnay ventilation, the OA Processing Unit is really two units in one, functioning as the main air conditioner when the load is light and

Pagina 37 - PUMY-P YKM-A(-BS)

SpecificationModelPower sourceCooling capacity Figure in < > is the recoverycapacity by LOSSNAY core.Heating capacityFigure in < > is th

Pagina 38 - PUHY-P YKB-A(-BS)

Remote ControllerIndividual Remote ControllerCentralised Remote Controller132Remote Controller

Pagina 39

The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs. Mitsubishi Elect

Pagina 40 - PUHY-P YSKB-A(-BS)

System ControllerMELANSUse of our MELANS products enhances efficiency and quality of air-conditioning, contributing to energy saving and reduction in

Pagina 41

Integrated Communications Control with Mitsubishi Electric's Unique Transmission Network (M-NET)*1. Group setting via wiring between Indoor unit

Pagina 42

IndividualRemote ControllerWired MA remote controller PAR-31MAAE• Temperature will be displayed either in Centigrade in 0.5- or 1-degree increments,

Pagina 43

Smart ME Controller PAR-U02MEDA• This Smart ME Controller is designed to control Mitsubishi Electric’s air conditioning units and also allows for the

Pagina 44

Simple remote controller PAC-YT52CRA (MA)• Dual set point When the operation mode is set to the Auto (dual set point) mode, two preset temperatures (

Pagina 45

PAR-FL32MA PAR-FA32MAPAR-SA9FA-E(4-way Cassette signal receiver)Wireless remote controller PAR-FL32MA / PAR-FA32MA / PAR-SA9FAExample of system config

Pagina 46

Equipment roomOffice compartmentOfficeOffice Meeting room BC controllerOutdoor unitRefrigerant piping: 2-pipe typeMeeting roomCoolingCoolingCoolingHea

Pagina 47

System structureAdvanced Touch controller AT-50BWith our new Advanced Touch Controller AT-50B, easy and simple operation via the touch panel offers an

Pagina 48

Three in OneThe following three features are integrated into AT-50B. ▪ Control up to 50 indoor units from one location ▪ A weekly programmable timer,

Pagina 49 - PUHY-EP YLM-A(-BS)

Control Screen for Power ConsumptionComparison in the number of connectable unitsCentralised controller AE-200E/AE-50EDimensions: 284(W) x 200(H) x 65

Pagina 50

System StructureFunctionsBACnet® is a registered trademark of ASHRAE.*1. Please contact your local distributor for when the feature is supported.Heate

Pagina 51 - PUHY-EP YSLM-A(-BS)

System structureSystem structureCentralised controller AG-150AWith a new coloured touch panel, and continuation of all the G-50A functions, the AG-150

Pagina 52

Backlit colour liquid crystal displayBacklight makes it easy to see and control units.One can identify whether a unit is ON or OFF from a distance.Con

Pagina 53

System exampleON/OFF remote controller PAC-YT40ANRACentralisedRemote ControllerFUNCTIONUNITSON/OFFERROR INDICATIONVENTILATION OPERATION(INDEPENDENT)VE

Pagina 54

Centralised controller EB-50GU-JThe Web Server Function enables Remote Operation or Scheduling Via a Web Browser on a Personal Computer. Up to 50 indo

Pagina 55

Annual / Weekly Schedule Enables Weekly and Annual scheduling with a registering license • The operations that can be scheduled for air condition

Pagina 56

Dimensions: 116(W) x 90(H) x 40(D) mm : 4-9/16(W) x 3-1/2(H) x 1-9/16(D) in.Advanced HVAC Controller (hereafter referred to as AHC)

Pagina 57 - (-BS)

Equipment roomOffice compartmentOfficeOffice Meeting room BC controllerOutdoor unitRefrigerant piping: 2-pipe typeMeeting roomCoolingCoolingCoolingHea

Pagina 58

Energy Saving Control (Peak Cut) Enables Energy Saving Control with the use of our new PI controller. (Registration of “Energy Management license pa

Pagina 59

Dimension: 200(W) x 120(H) x 45(D) mm : 7-7/8(W) x 4-3/4(H) x 1-13/16(D) in.No more PLCs are needed!Our new DIDO controller makes it p

Pagina 60 - PQHY-P YHM-A

Effective use of TG-2000A Multiple air conditioning charges in multiple buildings can be calculated. The power apportionment percentage data and appor

Pagina 61 - PQHY-P YSHM-A

LM-APLM-APM-NETLMAP04LM-APCITY MULTILM-APExample of System ConfigurationSystem design made simple through integration ofvarious devices into a total c

Pagina 62

BACnet® (BAC-HD150)System example (Connection of 150 units / groups with PAC-YG50ECA) CITY MULTI can easily combine into a Building Management System

Pagina 63

O ptional Parts155Optional Parts

Pagina 64

>>4-way cassette type (PLFY-VBM/VCM)>>2-way cassette type (PLFY-VLMD)>>Ceiling concealed type (PEFY-VMH(S))>>Ceiling suspended

Pagina 65

OPTIONAL PARTS FOR OUTDOOR UNITS>>For PUHY seriesDescription Remarks ModelBranch pipe (Header)Relay boxBase heater200 or below (Total capacity o

Pagina 66 - ZUBADAN (Heat Pump) Series(Y)

OPTIONAL EQUIPMENT FOR BC CONTROLLERBC Controller ModelCMB-P104V-G1, GB1CMB-P105V-G1CMB-P106V-G1CMB-P108V-G1, GA1, GB1CMB-P1010V-G1, GA1CMB-P1013V-G1,

Pagina 67 - PURY-P YLM-A(-BS)

Installation Information1. General precautions 1-1. Usage• The air conditioning systems described in this catalogue are designed and intended for hum

Pagina 68

“2-pipe” System ProvidesBetter Efficiency and PerformanceThe BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixtu

Pagina 69 - PURY-P YSLM-A(-BS)

1-5. Relevant Equipment• Use an earth leakage breaker (ELB) with medium sensitivity, and an activation speed of 0.1 seconds or less.• Consult your l

Pagina 70

2. Precautions for Indoor unit 2-1. Operating environment• The refrigerant (R410A) used for air conditioner is non-toxic and nonflammable. However, i

Pagina 71

3. Precautions for Fresh air intake type indoor unit 3-1. Usage• This unit mainly handles the outside air load, and is not designed to maintain the r

Pagina 72

4. Precautions for Outdoor Unit / Heat Source Unit 4-1. Installation Environment• Outdoor units with salt-resistant specification are recommended in

Pagina 73 - PURY-EP YLM-A(-BS)

5. Precautions for control-related items 5-1. Product specication• A consultation with BDT is required before installation of the MELANS system, par

Pagina 74

Maintenance EquipmentMaintenance cycle [Note that maintenance cycle does not mean guarantee period.]The following tables are applicable when using equ

Pagina 75 - PURY-EP YSLM-A(-BS)

B.S. Salt Protection Specications City Multi VRF Outdoor UnitsName Base materialPUHY, PURYSurface treatmentPaint thicknessYLM YLM-BSStandardSalt dama

Pagina 76

4 Wash the outdoor unit regularly.5 Repair any scratches on the panels.6 Inspect regularly. Paint or change parts as required.

Pagina 77

CM14AN-CFull Product Lineup CatalogueFull Product Lineup CatalogueThe Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certificati

Pagina 78 - PQRY-P YHM-A

“2-pipe” System ProvidesBetter Efficiency and PerformanceThe BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixtu

Pagina 79 - PQRY-P YSHM-A

What is Water-Cooled?It is possible now to combine the features of VRF with a water circuit using CITY MULTI WR2/WY. In this case the heat is rejected

Pagina 80

What is Water-Cooled?It is possible now to combine the features of VRF with a water circuit using CITY MULTI WR2/WY. In this case the heat is rejected

Pagina 81 - I ndoor Unit

Air conditioning is an ideal way of controlling the temperature, movement and cleanliness of air inside any building, large or small. With today'

Pagina 82 - P15Type Model name P20 P25

CMB-P-V-G1CMB-P-V-GA1CMB-P-V-HA1CMB-P-V-GB1CMB-P-V-HB1BC CONTROLLERIn many ways, the BC Controller is the technological heart of the CITY MULTI R2/WR2

Pagina 83

O utdoor UnitHeat Pump Series (Y)Heat Pump Series (S)Heat Pump Series - High COP (Y)Heat Pump Series - ZubadanHeat Recovery Series - High COP (R2)Wate

Pagina 84 - 4-way airflow

Heat PumpHeat PumpSLXLSLXLSSLXLSLXLHeat RecoveryHeat RecoveryAir CooledWaterCooledTypeSystemHPModelModel name3634323028262422201816P90038P95040P100042

Pagina 85

Heat PumpHeat PumpSLXLSLXLSSLXLSLXLHeat RecoveryHeat RecoveryAir CooledWaterCooledTypeSystemHPModelModel name3634323028262422201816P90038P95040P100042

Pagina 86 - PLFY-P VLMD-E

Y (Heat Pump) seriesCooling or HeatingLarge Offices (Y series)Outdoor unitIndoor unitBetween indoor units top-bottom differential15m [49ft] *4Furthest

Pagina 87

Equipment room Office compartmentOfficeOffice Meeting room BC controllerOutdoor unitRefrigerant piping: 2-pipe typeMeeting roomCoolingCoolingCoolingHe

Pagina 88 - 1-way airflow

Bringing year round comfort solutions to extreme climatesCITY MULTI ZUBADAN series combines the ultimate in application flexibility and pow

Pagina 89

ZUBADANStable Heating Performance even at -15°CExpanded Heating Operation down to -25°CUsing an industry first ‘Flash-injection Circuit’, the ZU

Pagina 90 - Low Static Ducted Units

Backup Function(HP400 and HP500 models)The ZUBADAN system ensures an exceptionally high level of reliability by utilizing a new backup function, which

Pagina 91

Maximum Stable OperationHeating up to250 min. straightReduced Defrosting timeBy utilizing our advanced Flash Injection Circuit, the system can

Pagina 92 - Mid Static Ducted Units

VRF systemVRF stands for Variable Refrigerant Flow. A VRF air conditioning system modulates the ow of refrigerant depending upon the capacity requir

Pagina 93

Y series & R2 series Features in Y (Heat Pump) series & R2 (Heat Recovery) seriesCompact DesignThe downsized outdoor unit can be transported t

Pagina 94 - High Static Ducted Units

Y series & R2 series The anti-corrosion Blue Fin treatment of the heat exchanger is especially effective in urban environments where traffic pollu

Pagina 95

inverterThe heat exchanger size has been extended horizontally, increasing the surface area.The shapes of the fan and grille of the outdoor unit have

Pagina 96 - PEFY-P VMH-E-F

inverterThe heat exchanger size has been extended horizontally, increasing the surface area.The shapes of the fan and grille of the outdoor unit have

Pagina 97

Water energy source system allows switchingbetween cooling and heatingThe WY-Series has all the benefits of the Y-Series using water source condensing

Pagina 98 - Under Ceiling Unit

Water Cooled SeriesThe new water cooled outdoor unit offers a greater efficiency with a higher COP compared to our YGM conventional model. System Pi

Pagina 99

OUTDOOR UNITS SeriesPUMY-P VKM-A(-BS) SpecificationsNotes:*1,*2 Nominal conditions*Nominal condition *1,*2 are subject to ISO 15042.*Due to continuing

Pagina 100 - Wall Mounted Type

OUTDOOR UNITS SeriesPUMY-P YKM-A(-BS) SpecificationsNotes:*1,*2 Nominal conditions*Nominal condition *1,*2 are subject to ISO 15042.*Due to continuing

Pagina 101 - Specifications

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 102 - Wall mounted type

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 103 - Connectable Models

Optimizing the capacity of the scroll compressor and modifying the winding of the compressor motor have led to the improvement in operating efficiency

Pagina 104 - Floor console

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 105

OUTDOOR UNITY SeriesPUHY-P YSKB-A(-BS) SpecificationsModel PUHY-P550YSKB-A (-BS) PUHY-P600YSKB-A (-BS) PUHY-P650YSKB-A (-BS)Power source3-phase 4-wire

Pagina 106 - Floor standing exposed

OUTDOOR UNITY SeriesPUHY-P YSKB-A(-BS) SpecificationsModel PUHY-P700YSKB-A (-BS) PUHY-P750YSKB-A (-BS) PUHY-P800YSKB-A (-BS)Power source3-phase 4-wire

Pagina 107

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 108 - Floor mounted concealed type

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 109 - Floor mounted 60Pa

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 110

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 111

OUTDOOR UNITY SeriesPUHY-P YSKB-A(-BS) SpecificationsModel PUHY-P1250YSKB-A (-BS) PUHY-P1300YSKB-A (-BS)Power source 3-phase 4-wire 380-400-415 V 50/

Pagina 112 - Air to Water series

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 113 - ATW UNIT

OUTDOOR UNITY Series - High COPPUHY-EP YLM-A(-BS) SpecificationsModel PUHY-EP200YLM-A (-BS) PUHY-EP250YLM-A (-BS) PUHY-EP300YLM-A (-BS)Power source 3

Pagina 114 - HEX UNIT

Optimizing the capacity of the scroll compressor and modifying the winding of the compressor motor have led to the improvement in operating efficiency

Pagina 115 - Indoor Unit

OUTDOOR UNITY Series - High COPPUHY-EP YLM-A(-BS) SpecificationsModel PUHY-EP350YLM-A (-BS) PUHY-EP400YLM-A (-BS) PUHY-EP450YLM-A (-BS)Power source 3

Pagina 116 - PWFY-P VM-E-BU

OUTDOOR UNITY Series - High COPPUHY-EP YSLM-A(-BS) SpecificationsModel PUHY-EP500YSLM-A (-BS) PUHY-EP550YSLM-A (-BS) PUHY-EP600YSLM-A (-BS)Power sour

Pagina 117 - PWFY-P VM-E1-AU

OUTDOOR UNITY Series - High COPPUHY-EP YSLM-A(-BS) SpecificationsModel PUHY-EP650YSLM-A (-BS) PUHY-EP700YSLM-A (-BS)Power source 3-phase 4-wire 380-4

Pagina 118 - PAR-W21MAA

OUTDOOR UNITY Series - High COPPUHY-EP YSLM-A(-BS) SpecificationsModel PUHY-EP750YSLM-A (-BS) PUHY-EP800YSLM-A (-BS)Power source 3-phase 4-wire 380-4

Pagina 119

OUTDOOR UNITY Series - High COPPUHY-EP YSLM-A(-BS) SpecificationsModel PUHY-EP850YSLM-A (-BS) PUHY-EP900YSLM-A (-BS)Power source 3-phase 4-wire 380-4

Pagina 120 - 16°C (60.8°F)

OUTDOOR UNITY Series - High COPPUHY-EP YSLM-A(-BS) SpecificationsNotes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa,

Pagina 121 - • Hyper Eco Core

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 122 - Why LOSSNAY is necessary

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 123 - 5 and 200RX5

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 124

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 125 - LGH-15~100RX5-E

VRF SystemsOur Answer to VRFDesigned and manufactured to the highest standards, the CITY MULTI range offers one of the most reliable air conditioning

Pagina 126

HEAT SOURCE UNITWY (Heat Pump) SeriesPQHY-P YHM-A SpecificationsModel PQHY-P200YHM-A PQHY-P250YHM-A PQHY-P300YHM-APower source3-phase 4-wire 380-400-4

Pagina 127 - 5-ELGH-15~100RX5-E

HEAT SOURCE UNITWY (Heat Pump) SeriesPQHY-P YSHM-A SpecificationsModel PQHY-P400YSHM-A PQHY-P450YSHM-A PQHY-P500YSHM-APower source3-phase 4-wire 380-4

Pagina 128 - Centralized Controller System

HEAT SOURCE UNITWY (Heat Pump) SeriesPQHY-P YSHM-A SpecificationsModel PQHY-P550YSHM-A PQHY-P600YSHM-APower source3-phase 4-wire 380-400-415V 50/60Hz

Pagina 129 - PAC-AH-M-J

HEAT SOURCE UNITWY (Heat Pump) SeriesPQHY-P YSHM-A SpecificationsModel PQHY-P650YSHM-A PQHY-P700YSHM-APower source3-phase 4-wire 380-400-415V 50/60Hz

Pagina 130 - OA Processing

Model PQHY-P750YSHM-A PQHY-P800YSHM-APower source3-phase 4-wire 380-400-415V 50/60Hz 3-phase 4-wire 380-400-415V 50/60HzCooling capacity *1kW 85.0 90

Pagina 131 - Specification

Model PQHY-P850YSHM-A PQHY-P900YSHM-APower source3-phase 4-wire 380-400-415V 50/60Hz 3-phase 4-wire 380-400-415V 50/60HzCooling capacity *1kW 96.0 10

Pagina 132

Notes:*1,*2 Nominal conditions*3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2O). *Nominal condition *1,*2 are subject

Pagina 133 - The Importance of Control

OUTDOOR UNITR2 SeriesPURY-P YLM-A(-BS) SpecificationsModel PURY-P200YLM-A (-BS) PURY-P250YLM-A (-BS)Power source 3-phase 4-wire 380-400-415 V 50/60 H

Pagina 134 - System Controller

OUTDOOR UNITR2 SeriesPURY-P YLM-A(-BS) SpecificationsModel PURY-P300YLM-A (-BS) PURY-P350YLM-A (-BS)Power source 3-phase 4-wire 380-400-415 V 50/60 H

Pagina 135

OUTDOOR UNITR2 SeriesPURY-P YSLM-A(-BS) SpecificationsModel PURY-P400YSLM-A (-BS) PURY-P450YSLM-A (-BS) PURY-P500YSLM-A (-BS)Power source 3-phase 4-w

Pagina 136 - Individual

VRF SystemsOur Answer to VRFDesigned and manufactured to the highest standards, the CITY MULTI range offers one of the most reliable air conditioning

Pagina 137 - :Not available

OUTDOOR UNITR2 SeriesPURY-P YSLM-A(-BS) SpecificationsModel PURY-P550YSLM-A (-BS) PURY-P600YSLM-A (-BS) PURY-P650YSLM-A (-BS)Power source 3-phase 4-w

Pagina 138

OUTDOOR UNITR2 SeriesPURY-P YSLM-A(-BS) SpecificationsModel PURY-P700YSLM-A (-BS) PURY-P750YSLM-A (-BS) PURY-P800YSLM-A (-BS)Power source 3-phase 4-w

Pagina 139 - PAR-SL94B-E

OUTDOOR UNITR2 SeriesPURY-P YSLM-A(-BS) SpecificationsModel PURY-P850YSLM-A (-BS) PURY-P900YSLM-A (-BS)Power source 3-phase 4-wire 380-400-415 V 50/6

Pagina 140 - Centralised

OUTDOOR UNITR2 Series - High COPPURY-EP YLM-A(-BS) SpecificationsModel PURY-EP200YLM-A (-BS) PURY-EP250YLM-A (-BS) PURY-EP300YLM-A (-BS)Power source

Pagina 141 - Advanced Functions

OUTDOOR UNITR2 Series - High COPPURY-EP YLM-A(-BS) SpecificationsModel PURY-EP350YLM-A (-BS) PURY-EP400YLM-A (-BS) PURY-EP450YLM-A (-BS)Power source

Pagina 142

OUTDOOR UNITR2 Series - High COPPURY-EP YSLM-A(-BS) SpecificationsModel PURY-EP500YSLM-A (-BS) PURY-EP550YSLM-A (-BS) PURY-EP600YSLM-A (-BS)Power sou

Pagina 143 - Functions

OUTDOOR UNITR2 Series - High COPPURY-EP YSLM-A(-BS) SpecificationsModel PURY-EP650YSLM-A (-BS) PURY-EP700YSLM-A (-BS) PURY-EP750YSLM-A (-BS)Power sou

Pagina 144

OUTDOOR UNITR2 Series - High COPPURY-EP YSLM-A(-BS) SpecificationsModel PURY-EP800YSLM-A (-BS) PURY-EP850YSLM-A (-BS) PURY-EP900YSLM-A (-BS)Power sou

Pagina 145 - Mode selection

HEAT SOURCE UNITWR2 (Heat Recovery) SeriesPQRY-P YHM-A SpecificationsModel PQRY-P200YHM-A PQRY-P250YHM-A PQRY-P300YHM-APower source3-phase 4-wire 380-

Pagina 146

HEAT SOURCE UNITWR2 (Heat Recovery) SeriesPQRY-P YSHM-A SpecificationsModel PQRY-P400YSHM-A PQRY-P450YSHM-A PQRY-P500YSHM-APower source3-phase 4-wire

Pagina 147 - EB-50GU-J (without display)

I nverter Driven Compressor TechnologyUsing inverter driven technologysaves energy in several ways:The unique Heat Interchange Circuit (HIC) enhances

Pagina 148 - GB-50ADA-J (without display)

HEAT SOURCE UNITWR2 (Heat Recovery) SeriesPQRY-P YSHM-A SpecificationsModel PQRY-P550YSHM-A PQRY-P600YSHM-APower source3-phase 4-wire 380-400-415V 50/

Pagina 149 - HVAC Controller

I ndoor UnitCeiling cassette type 4-way airflow Ceiling cassette type 2-way airflow Ceiling cassette type 1-way airflow Ceiling concealed typeFresh Ai

Pagina 150 - Control Modules

Ceiling Cassette4-way air flow2-way air flow1-way air flowPLFY-P VBM-EPLFY-P VCM-E2PLFY-P VLMD-EPMFY-P VBM-ECeiling ConcealedPEFY-P VMS1(L)-EPEFY-P VM

Pagina 151

Ceiling Cassette4-way air flow2-way air flow1-way air flowPLFY-P VBM-EPLFY-P VCM-E2PLFY-P VLMD-EPMFY-P VBM-ECeiling ConcealedPEFY-P VMS1(L)-EPEFY-P VM

Pagina 152 - TG-2000 Computer

PLFY-P VBM-EPLFY-P VCM-E2INDOOR UNITCeiling cassette type4-way airflow The new 4-way cassette VBM offers 72 different airflow patterns, making it idea

Pagina 153 - BMS Interface Modules

PLFY-P VBM-EPLFY-P VCM-E2INDOOR UNITCeiling cassette type4-way airflow The new 4-way cassette VBM offers 72 different airflow patterns, making it idea

Pagina 154 - and M-NET adapter

INDOOR UNITCeiling cassette type2-way airflow PLFY-P VLMD-EFresh air can be taken in to the main unit directly (optional accessories needed.)The drain

Pagina 155 - O ptional Parts

SpecificationsNotes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27°C(81°F)

Pagina 156 - Optional Parts

mm (in.)198(7-13/16)PMFY-VBM230(9-11/16)max.402(15-7/8)max.600 (23-5/8)Compact and lightweight body perfect for limited ceiling space applications.Uni

Pagina 157

SpecificationsNotes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27°C(81°F)

Pagina 158 - OPTIONAL PARTS FOR CONTROL

I nverter Driven Compressor TechnologyUsing inverter driven technologysaves energy in several ways:The unique Heat Interchange Circuit (HIC) enhances

Pagina 159 - Installation Information

The ultra thin unit of 200mm offers increased flexibility, and is particularly suitable for places where low noise operation is desired from a slim li

Pagina 160

Specifications *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor : 27°CD.B./

Pagina 161

PEFY-P VMA(L)-EINDOOR UNITMid Static Ducted UnitsPrecise control of indoor temperatures while operating with optimum energy usage, offering a high-ene

Pagina 162

SpecificationsLiquid (R410A)(R22,R407C)Gas (R410A)(R22,R407C)Type x QuantityAirflow rate(Low-Mid-High)External staticpressureTypeOutput CoolingHeating

Pagina 163

Capacity P503427P633832P713932P804135P1004234P1254234P1404234Sound pressureLeveldB(A)Sound pressure level table (Standard static pressure 220V)HighLow

Pagina 164 - 5-2. Installation Environment

SpecificationsNotes: *1 Cooling/heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor :

Pagina 165 - Maintenance Equipment

Fresh Air can be taken in with temperature control. Ideal for Offices, Stores and Restaurants.The Fresh Air intake indoor unitcan be installed in any

Pagina 166 - City Multi VRF Outdoor Units

SpecificationsNotes: 1. The cooling and heating capacites are the maximum capacites that were obitained by operating in the above air conditions and w

Pagina 167

Designed for ultra-quiet operation and easy maintenance, providing exceptional comfort.PCFY-P VKM-EINDOOR UNITUnder Ceiling UnitSleek and slim with st

Pagina 168 - CM14AN-C

SpecificationsNotes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor : 27°C(80.6°