TECHNICAL & SERVICE MANUAL
Air-Conditioners For Building Application
<Indoor unit>
PFFY-P25VLEM-A,PFFY-P25VLRM-A
PFFY-P20VLEM-A,PFFY-P20VLRM-A
PFFY-P32VLEM-A,PFFY-P32VLRM-A
PFFY-P40VLEM-A,PFFY-P40VLRM-A
PFFY-P50VLEM-A,PFFY-P50VLRM-A
PFFY-P63VLEM-A,PFFY-P63VLRM-A
2001
Models
Floor Standing Type
Series PFFY
CONTENTS
SAFETY PRECAUTIONS ·························1
1. FEATURES············································3
2. PART NAMES AND FUNCTIONS ········4
3. SPECIFICATION ···································6
4. OUTLINES AND DIMENSIONS············8
5. WIRING DIAGRAM ·····························10
6.
REFRIGERANT SYSTEM DIAGRAM
····11
7. TROUBLE SHOOTING························12
8. DISASSEMBLY PROCEDURE ···········17
For use with the R407C & R22
Exposed type
Concealed type
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Series PFFY

TECHNICAL & SERVICE MANUALAir-Conditioners For Building Application<Indoor unit>PFFY-P25VLEM-A,PFFY-P25VLRM-APFFY-P20VLEM-A,PFFY-P20VLRM-APF

Pagina 2 - SAFETY PRECAUTIONS

151580Duct mounting hole2 ✕ F - ø 4.79400167310 90A132 15Floor mounting holeOD ø27(TOP ø20)Hose(accessory)StrainerDrain panAir filterWall mounting hol

Pagina 3 - R407C refrigerant

10Switch(for voltage selection)Aux.relay POWER SUPPLY~ 220-240V 50Hz~ 208-230V 60HzBREAKER(16A)FUSE(16A)PULL BOXTO NEXT INDOOR UNITSwitch (connectio

Pagina 4

11Strainer (#100mesh)Strainer (#100mesh)Heat exchangerRoom temparature thermistor TH21Gas pipe thermistor TH23Liquid pipe thermistor TH22Linear expans

Pagina 5 - PART NAMES AND FUNCTIONS2

12Room temparaturethermistor (TH21)Liquid pipe thermistor(TH22)Gas pipe thermistor(TH23)TransformerFan motorLinear expansionvalveDisconnect the connec

Pagina 6 - ERROR CODE

1301020304050-20 -10 0 10 20 30 40 50< Thermistor for lower temperature >Temperature (: )Resistance (k Ω )4ø4365ø32ø21ø1ø4ø3ø2ø1Controller board

Pagina 7 - SPECIFICATION3

Output(Phase)Outputø11ONø2ONø3OFFø4OFF2OFFONONOFF3OFFOFFONON4ONOFFOFFON<Output pulse signal and the valve operation>➁Linear expansion valve oper

Pagina 8

15123456789101~6123456781~4Thermistor<Intake temperaturedetection>positionON OFFFilter crogging detection Provided Not providedFilter life 2,500

Pagina 9 - OUTLINES AND DIMENSIONS4

16321SWC123(SWA)0594837261SW12100594837261SW11108F7E6D5C4B3A291SW143210594837261SW120594837261SW1108F7E6D5C4B3A291SW14Address boardAddress boardAddres

Pagina 10 - PFFY-P20·25·32·40·50·63VLRM-A

(A)(B)Fig.1Fig.2Fig.3(A)DISASSEMBLY PROCEDURE88-1 CONTROL BOX (Exposed type PFFY-P·VLEM)Be careful removing heavy parts.1.Removing the front panel (A

Pagina 11 - WIRING DIAGRAM5

18(D)(C)(E)(F)Fig.1Fig.2Fig.3Fig.4(A)(B)(B)8-2 THERMISTOR (Gus and liquid piping temperature detection)1.Removing the side casing(1)Open the control p

Pagina 12 - REFRIGERANT SYSTEM DIAGRAM6

1- Inadequate connection and fastening may generate heat andcause a fire.• Prepare for typhoons and other strong winds and earthquakesand install the

Pagina 13 - 7 TROUBLE SHOOTING

19Be carefulThermistorFig.1Fig.1Fig.2➀OPERATING PROCEDURE PHOTOS1.Removing the drainpan(1)Remove the fixing screw of the side frame by thecontrol box.

Pagina 14 - Linear expansion valve

Fig.1(a)(a)➀(A)fan motor shaftfixing screwFig.2(b)(b)(c)(c)20OPERATING PROCEDURE PHOTOS8-5 FAN and FAN MOTOR1.Sliding the fan section (Fig.1)(1)Remove

Pagina 15

Fig.1Fig.2Fig.3Cover 1Cover 221OPERATING PROCEDURE PHOTOS8-6 HEAT EXCHANGER1.Removing the casing (1)Remove the fixing screws(six) and remove thecasing

Pagina 16

Fig.1Fig.2Fig.3(A)(B)22OPERATING PROCEDURE PHOTOS8-7 CASING (Concealed type PFFY-P·VLRM)1.Removing the casing ass’y(1)Remove the fixing screws (nine)

Pagina 17 - Address board

HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANIssued in May. 2001 MEE01K053Printed in JapanNew publication,

Pagina 18 - DISASSEMBLY PROCEDURE8

22. Precautions for devices that useR407C refrigerantCaution:• Do not use the existing refrigerant piping.- The old refrigerant and refrigerator oil i

Pagina 19 - OPERATING PROCEDURE PHOTOS

3PFFY-P20VLEM-A,PFFY-P20VLRM-APFFY-P25VLEM-A,PFFY-P25VLRM-APFFY-P32VLEM-A,PFFY-P32VLRM-APFFY-P40VLEM-A,PFFY-P40VLRM-APFFY-P50VLEM-A,PFFY-P50VLRM-APFFY

Pagina 20 - PHOTOSOPERATING PROCEDURE

4● ● ● Remote Indoor (Main) Unitcontroller[PAR-20MAA]Once the controls are set, the same operation mode canbe repeated by simply pressing the ON/OFF b

Pagina 21 - 8-5 FAN and FAN MOTOR

5● DisplayON/OFF CENTRALLY CONTROLLEDERROR CODECLOCKON OFF°CCHECKCHECK MODEFILTERTEST RUNFUNCTION°C1Hr.NOT AVAILABLESTAND BY DEFROSTTEMP.ABCDEFHIKLJMP

Pagina 22 - 8-6 HEAT EXCHANGER

6Power sourceModelPFFY-P20VLEM-APFFY-P25VLEM-APFFY-P32VLEM-APFFY-P40VLEM-APFFY-P63VLEM-AItemDimensionFanMotorRefrigerantpipe dimensionPower consumptio

Pagina 23

7LEVC1 1.5µF X 440V2.5µFX440V2.0µFX440VMF1,2PFFY-P20VLEM-AVLRM-APFFY-P63VLEM-AVLRM-APFFY-P50VLEM-AVLRM-APFFY-P40VLEM-AVLRM-APFFY-P32VLEM-AVLRM-APFFY-P

Pagina 24 - Printed in Japan

878CRemote controller(PAR-F25MA)can be built-in.(Program timer can not bebuilt-in together)ø6.35ø12.77307207601170PFFY -P63VLEM-APFFY -P40VLEM-A1410 1