SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················5
3. SPECIFICATION·················································5
4. NOISE CRITERIA CURVES·······························6
5. OUTLINES AND DIMENSIONS ·························7
6. WIRING DIAGRAM ············································7
7. REFRIGERANT SYSTEM DIAGRAM················8
8. PERFORMANCE CURVES································9
9. MICROPROCESSOR CONTROL ····················20
10. SERVICE FUNCTIONS·····································22
11. TROUBLESHOOTING······································22
12. DISASSEMBLY INSTRUCTIONS·····················29
13. PARTS LIST······················································32
Wireless type
Models
MUH-A07YV -
MUH-A09YV -
MUH-A12YV -
E1
E1
E1
No. OB331
HFC
utilized
R410A
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
MUH-A07YV -
MUH-A09YV -
MUH-A12YV -
E1
E1
E1
Indication of
model name
NOTE:
•This manual describes technical data of outdoor units.
•As for indoor units MSC-A07/A09/A12YV - , refer to the service manual OB329.
E1
OB331-1.qxp 03.12.3 1:20 PM Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - MUH-A12YV

SERVICE MANUALCONTENTS1. TECHNICAL CHANGES ····································22. PART NAMES AND FUNCTIONS······················53. SPECIFICATION····

Pagina 2 - TECHNICAL CHANGES

10MSC-A07YV - E1MUH-A07YV - E1 MUH-A12YV - E1 MSC-A12YV - E1MUH-A09YV - E1 MSC-A09YV - E18.57.87.16.45.85.19.68.88.07.26.55.711.010.09.18.27.46.520.41

Pagina 3

118-2.OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENTCOOL operation① Both indoor and outdoor unit are under the same temperature/humidity condition.➁ Ai

Pagina 4 - 5.Additional charge

12HEAT operationCondition indoor:Dry bulb temperature 20.0°CWet bulb temperature 14.5°COutdoor:Dry bulb temperature 7,15,20°CWet bulb temperature 6,12

Pagina 5 - SPECIFICATION

13MSC-A07YV - : MUH-A07YV -E1E1PERFORMANCE DATACOOL operation (230V)21 18 2.70 1.51 0.56 572 2.59 1.45 0.56 601 2.48 1.39 0.56 629 2.39 1.34 0.56 6

Pagina 6 - NOISE CRITERIA CURVES

14MSC-A07YV - : MUH-A07YV -E1E1PERFORMANCE DATACOOL operation (230V)21 18 2.25 1.26 0.56 701 2.07 1.16 0.56 744 1.99 1.11 0.56 75821 20 2.37 1.04 0

Pagina 7 - WIRING DIAGRAM

15MSC-A09YV - : MUH-A09YV -E1E1PERFORMANCE DATACOOL operation (230V)21 18 3.00 1.56 0.52 636 2.87 1.49 0.52 668 2.75 1.43 0.52 700 2.65 1.38 0.52 7

Pagina 8 - REFRIGERANT SYSTEM DIAGRAM

16MSC-A09YV - : MUH-A09YV -E1E1PERFORMANCE DATACOOL operation (230V)21 18 2.50 1.30 0.52 779 2.30 1.19 0.52 827 2.21 1.15 0.52 84321 20 2.63 1.05 0

Pagina 9 - PERFORMANCE CURVES

17MSC-A12YV - : MUH-A12YV -E1E1PERFORMANCE DATACOOL operation (230V)21 18 4.11 1.97 0.48 872 3.94 1.89 0.48 916 3.78 1.81 0.48 959 3.64 1.75 0.48 1

Pagina 10 - Wet-and dry-bulb

18MSC-A12YV - : MUH-A12YV -E1E1PERFORMANCE DATACOOL operation (230V)21 18 3.43 1.65 0.48 1068 3.15 1.51 0.48 1134 3.03 1.45 0.48 115521 20 3.61 1.3

Pagina 11

19MSC-A07YV - : MUH-A07YV -E1E1PERFORMANCE DATAHEAT operation (230V)MSC-A09YV - : MUH-A09YV -E1E1OUTDOOR WB(:)INDOOR-10 -5 0 5 10 15 20DB(:)Q

Pagina 12 - Ambient temperature(˚C)

TECHNICAL CHANGES21RefrigeratingoilRefrigerantNew refrigerantR410AHFC-32: HFC-125 (50%:50%)Pseudo-azeotropic refrigerantNot includedA1/A172.6-51.41.55

Pagina 13 - MSC-A07YV - : MUH-A07YV

2. DefrostingDefrosting of outdoor heat exchanger is controlled by DEICER P.C. board, with detection by the defrost thermistor RT61.(1) Starting condi

Pagina 14

21NOTE ● When the indoor coil thermistor RT12 reads above 0°C, indoor fan operates at Very Low for 30 seconds.● When the indoor coil thermistor RT12 r

Pagina 15 - MSC-A09YV - : MUH-A09YV

TROUBLESHOOTING113. Troubleshooting procedure1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an

Pagina 16

2311-2. Instruction of troubleshootingStartIndoor unit operates.Outdoor unit doesn't operate.Indoor unit doesn't receive the signal from re

Pagina 17 - MSC-A12YV - : MUH-A12YV

AACheck of outdoor unitCompressor and/or outdoor fan motor doesn’t operate.YesCompressor doesn't operate.YesYesIs there 230V AC between 3 on the

Pagina 18

25BB Check of outdoor unitDoes compressor stop?NoYesIs there 230V AC between 3 on thecompressor contactor (52C) and N on the outdoor terminal block (

Pagina 19

26DDHow to check mis-wiring and serial signal errorMis-wiring is indicated.(0.5-sec. ON, 0.5-sec. OFF)1. Turn OFF the power supply(indoor/outdoor unit

Pagina 20 - MICROPROCESSOR CONTROL

27EE Check of outdoor thermistorMeasure resistance between CN 661 1 and 2.NoYesReplace the thermistor.Defrost thermistor (RT61)Reconnect CN661.Turn O

Pagina 21

28MUH-A07YV -MUH-A09YV -MUH-A12YV -Outdoor deicer P.C. boardE1E1E1CN711Outdoor fan motor 230V ACCN721R.V. coil230V ACF61Fuse2A/250V}}CN661 1-2Defro

Pagina 22 - SERVICE FUNCTIONS

29DISASSEMBLY INSTRUCTIONS12MUH-A07YV - MUH-A09YV - MUH-A12YV -OUTDOOR UNITE1E1E1OPERATING PROCEDURE PHOTOS1. Removing the cabinet(1) Remove the screw

Pagina 23 - MUH-A12YV

3-30 -20 -10 0 10 203040 50 60-0.50.00.51.01.52.02.53.03.54.0(MPa [Gauge])R410AR22Conversion chart of refrigerant temperature and pressureSaturated li

Pagina 24 - Check of outdoor unit

303. Removing the propeller and the outdoor fan motor(1) Remove the cabinet. (Refer to 1.)(2) Remove the propeller nut.(3) Remove the propeller.NOTE :

Pagina 25

31OPERATING PROCEDURE PHOTOS4. Removing the compressor(1) Remove the cabinet. (Refer to 1.)(2) Remove the relay panel.(3) Remove the soundproof felt.(

Pagina 26

32PARTS LIST13No.Part No.Remarks123456789101112131415E02 835 630E02 836 630E02 837 630E02 815 232E02 815 521E02 742 900E02 753 900E02 7

Pagina 27 - Check of outdoor thermistor

331234567891011E02 665 501E02 835 301E02 672 301E02 752 353E02 694 353E02 696 353E02 835 451E02 836 451E02 128 383E02 817 374E02

Pagina 28

OB331-2.qxp 03.12.3 1:22 PM Page 34

Pagina 29 - DISASSEMBLY INSTRUCTIONS

OB331-2.qxp 03.12.3 1:22 PM Page 35

Pagina 30 - OPERATING PROCEDURE PHOTOS

CCCopyright 2003 MITSUBISHI ELECTRIC ENGINEERING CO.,LTDDistributed in Dec. 2003. No.OB331 6Made in JapanNew publication, effective Dec. 2003Specifica

Pagina 31

4Electronic scale for refrigerant chargingOutdoor unitRefrigerant gas cylinderoperating valveRefrigerant gas cylinderfor R410A with siphonRefrigerant

Pagina 32 - PARTS LIST

5PART NAMES AND FUNCTIONS2Air inletPipingDrain hoseAir outletDrain outlet(back and side)OUTDOOR UNITMUH-A07YV -MUH-A09YV -MUH-A12YV -E1E1E1ACCESSORIES

Pagina 33

NOISE CRITERIA CURVES6490807060504030201063 125 250 500 1000 2000 4000 8000APPROXIMATETERESHOLD OFHEARING FORCONTINUOUSNOISENC-60NC-50NC-40NC-30NC-20N

Pagina 34

7OUTLINES AND DIMENSIONS5WIRING DIAGRAM6MODELS WIRING DIAGRAMSYMBOLT61TB1,TB221S452CSYMBOLMFNR61RT61SR61,SR62SYMBOLC1C65DSARF61MCNAMENAME NAMECOMPRESS

Pagina 35

REFRIGERANT SYSTEM DIAGRAM87Unit:mmMUH-A12YV -E1OUTDOOR UNIT(with heat insulator)(with heat insulator)Refrigerant pipe [12.74-way valveStop valve(wit

Pagina 36

9 Piping size O.D : mm Length of connecting pipe : mModelRefrigerant pipingMax. length : m A2025Indoor unitGas 0.43Liquid 0.5 Gas9.5212.7Liquid6.35