(1) Common items**
Certain restrictions (vertical separation between indoor and outdoor units, operable temperature
range etc.) apply, depending on where the outdoor unit is installed. Models available for 60/90*
meters of vertical separation between indoor and outdoor units are listed in appropriate manuals.
*Outdoor unit below indoor unit = 60 m (196 ft); Outdoor unit above indoor unit = 90 m (295 ft)
(2) Y series**
Certain restrictions (pipe diameter, maximum piping length etc.) apply, depending on where the
outdoor unit is installed.
Refer to the table at right (DIP SW settings) for how to set the dipswitches on the outdoor unit.
(3) R2 series**
Certain restrictions (maximum total capacity of indoor units) apply, depending on where the
outdoor unit is installed.
Refer to the table at right (DIP SW settings) for how to set the dipswitches on the outdoor unit.
Turn DIP SW 6-1 to ON on the G-, GA-, and HA-type BC controllers.
Use the BC controller (G/GA types) with the serial number 81W***** or later.
If the BC controller (G/GA types) has a serial number before 81W*****, replace the circuit board.
**Refer to appropriate manuals for details.
The following parts are included in the kit. Please check.
No.
1 2 3 4 5 6 7
External appearance
Parts
name
Medium pressure
sensor assy
Function setting
connector
Function setting
connector
Function setting
connector
Label Band Pipe cover
Qty. 1 1 1 1 1 2 1
List of necessary parts for different models
No. Parts
Model group
A B C D E F G H J K L M N P Q
1
Medium pressure sensor assembly ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
2
Function setting connector (wire color: red x white) ○ ○ ○ - - - - - - - - - - -
3
Function setting connector (wire color: red x black) - - - - ○ ○ ○ - - - - - - - -
4
Function setting connector (wire color: black x black) - - - - - - - ○ ○ ○ - - - -
5
Label ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
6
Band (for control box guard (refer to Figure 4) and Pipe cover) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ - - - -
7
Pipe cover (buffer) - - - - - - - - - - - - - - -
*Refer to Item (6) under “Installation Procedures” on page 2 for how to install item 7.
* Note that which mounting plate and function setting connector is used depends on the model. Refer to the table below (Model group list) for the
detailed information on Model groups.
If the wrong type of function setting connector is connected, the unit will not properly operate or it will come to an abnormal stop.
[Models group list]
Group A Group B Group C Group D
Model Model Model Model
PUHY-P200/250YHM-A PUHY-P300YHM-A PUHY-P350/400/450YHM-A PURY-P250/300/350/400YHM-A
PUHY-P72/96T(Y)HMU-A PUHY-P120T(Y)HMU-A PURY-P96/120T(Y)HMU-A
PURY-P200YHM-A
PURY-P72T(Y)HMU-A
Group E Group F Group G Group H
Model Model Model Model
PUHY-EP200YHM-A PUHY-EP250/300YHM-A PURY-EP250/300YHM-A PUHY-P200/250YJM-A
PURY-EP200YHM-A PUHY-EP200YJM-A
PUHY-P72/96T(Y)JMU-A
Group J Group K Group L Group M
Model Model Model Model
PUHY-P300YJM-A PUHY-P350/400/450YJM-A PURY-P250/300/350/400/450YJM-A PUHY-P72/96T(Y)KMU-A
PUHY-P120/144T(Y)JMU-A PUHY-EP250/300YJM-A PURY-EP250/300/350YJM-A PUHY-EP200/250YKM-A
PURY-P200YJM-A PURY-P96/120/144T(Y)JMU-A PUHY-P200/250/300YKC-A
PURY-EP200YJM-A PUHY-P200/250/300YLKC-A
PURY-P72T(Y)JMU-A PUHY-P300/350YRKC-A
PUCY-P200/250/300YKA.TH
Group N Group P Group Q
Model Model Model
PUHY-P120/144T(Y)KMU-A PURY-P72/96/120/144T(Y)KMU-A PUHY-P350/400/450YKC-A
PUHY-EP300/350/400/450YKM-A
PURY-EP200/250/300/350/400/450YKM-A
PUHY-P350/400/450YEKC-A
PUHY-P350/400/450YLKC-A
PUHY-P400/450YRKC-A
PUCY-P350/400/450/500YKA.TH
MITSUBISHI ELECTRIC MULTI AIR CONDITIONERS OPTIONAL PARTS
(For applications with a vertical separation between indoor and outdoor units up to 60/90 m)
Medium pressure sensor installation manual
PAC-KBU91MH-E
[DIP SW settings]
Model
Control box
(Outdoor unit)
Control box
(BC controller)
PUHY-(E)P***YHM-A(-BS)
2-3 ON
-
PUHY-P***YHMU-A(-BS)
PUHY-(E)P***YJM-A(-BS)
PUHY-P***T(Y)JMU-A(-BS)
PURY-(E)P***YHM-A(-BS)
6-1 ON
PURY-P***YHMU-A(-BS)
PURY-(E)P***YJM-A(-BS)
PURY-P***T(Y)JMU-A(-BS)
PUHY-P***T(Y)KMU-A(-BS)
6-3 ON
-
PUHY-EP***YKM-A(-BS)
PUHY-P***Y(E)KC-A
PUHY-P***YLKC-A
PUHY-P***YRKC-A
PUCY-P***YKA.TH(-BS)(-T)
PURY-P***T(Y)KMU-A(-BS)
6-1 ON
PURY-EP***YKM-A(-BS)
(1/2) WT06787X03
white
black
red red
black
black
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - PAC-KBU91MH-E

(1) Common items**Certain restrictions (vertical separation between indoor and outdoor units, operable temperature range etc.) apply, depending on whe

Pagina 2

[Installation Procedures]Install the sensor according to the procedures below.(1) Turn off the power of the unit, and remove the top panel, bottom pan