Mitsubishi Electric PUHZ-RP100VHA2 Manual de usuario

Busca en linea o descarga Manual de usuario para Acondicionadores de aire del sistema de división Mitsubishi Electric PUHZ-RP100VHA2. PLASERIES Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 1
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
51 52
New 4-Way Ceiling Cassette
Previous
model
PUHZ-P125/140/200/250
PUHZ-RP100/125/140/200/250
PUH-P125/140PUH-P71/100
PU-P125/140PU-P71/100
PUHZ-RP60/71
Standard 4-way Cassette
PUHZ-RP35/50
SUZ-KA50/60/71 PUHZ-P100SUZ-KA35
Deluxe 4-way Cassette Line-up
For customers seeking much higher energy-savings, Mitsubishi Electric offers a variety of deluxe units in this series line-up: models 75–125.
Compared to the standard model (100), deluxe models provide an additional energy savings of approximately 20%, contributing to a significant
reduction in electricity costs.
Compared to the standard model (100), the deluxe 4-way ceiling cassette
power inverter series provides an approximate 20% improvement in energy
efficiency, adding to even further reductions in electricity consumption.
Automatic Air-speed Adjustment
An automatic air-speed mode that adjusts airflow speed automati-
cally is adopted to maintain comfortable room conditions at all
times. This setting automatically adjusts the air-speed to conditions
that match the room environment.
Horizontal Airflow
A “Horizontal Airflow” function has been
added to reduce drafty-feeling distribution.
Horizontal Airflow prevents cold drafts from
striking the body directly, thereby keeping
the body from becoming over-chilled.
Equipped with High- and Low-ceiling Modes
Units are equipped with high- and low-ceiling operation modes that make it possible to switch the airflow volume to match room height. The ability
to choose the optimum airflow volume makes it possible to optimize the breezy sensation felt throughout the room.
Wave Airflow – Thoroughly warming all corners of the room!
Wave Airflow Operation
“Wave Airflow” is essentially the advanced control of the vanes
directing the airflow from the unit. Blown-air is repeated dispersed
from the unit in horizontal and downward directions at time-lagged
intervals to provide uniform heating throughout the room.
Optimum Airflow
Individual Vane Settings
Optimum airflow settings provide maximum
comfort throughout the room.
In addition to the selection of variable airflow patterns (i.e., 2-,
3- or 4-way), this function allows the independent selection of
vertical airflow levels for each vane, thereby maintaining a com-
fortable room environment with even temperature distribution.
Wide Airflow
Wide-angle outlets distribute airflow
to all corners of the room.
The outlets are larger than those of previous
models and the shape has been improved for
better wide-angle ventilation.
At the start of heating/cooling opera-
tion, the airflow is set to high-speed
to quickly heat/cool the room.
When the room temperature reaches
the desired setting, the airflow speed
is decreased automatically for stable
comfortable heating/cooling operation.
The “i-see Sensor” is an innovative Mitsubishi Electric technology
that uses a radiation-based sensor to monitor temperature through-
out an entire room. When connected to the air conditioner control
panel, i-see Sensor works to maximize room comfort.
“ ” temperature-sensing
technology improves energy efficiency
and enhances room comfort
An automatic grille lowering function is avail-
able for easy filter maintenance. Special
wired and wireless remote controllers can
be used to lower the grille for maintenance.
The grille can be lowered a maximum of 4m from the
ceiling in 8 steps, thus enabling easy cleaning of the air
filter. Cleaning of the filter is an important factor for
saving energy.
Automatic Grille Lowering
Function (PLP-6BAJ)
“Rank A” Energy Savings Achieved for Range of Full-capacity Models
In addition to the deluxe indoor units, models in the full-capacity range have also attained the “Rank A” energy savings rating. This contributes
greatly to reducing electricity costs regardless of building size.
Cooling
Heating
Rank ARank A Rank A Rank A Rank A Rank A
EER
3.66
COP
4.21
EER
3.36
COP
3.66
EER
3.23
COP
3.61
EER
3.75
COP
3.85
EER
3.74
COP
4.21
EER
4.18
COP
4.61
EER
3.41
COP
4.00
PLA-RP35BA
PUHZ-RP35VHA4
PLA-RP50BA
PUHZ-RP50VHA4
PLA-RP60BA2
PUHZ-RP60VHA4
PLA-RP71BA2
PUHZ-RP71VKA
PLA-RP100BA3
PUHZ-RP100YKA
PLA-RP125BA2
PUHZ-RP125YKA
Rank A
EER
3.21
COP
3.70
PLA-RP140BA2
PUHZ-RP140YKA
Rank A
EER
3.45
COP
3.93
PLA-RP100BA3x 2
PUHZ-RP200YKA
Rank A
EER
3.22
COP
3.61
PLA-RP125BA2x 2
PUHZ-RP250YKA
PLA
SERIES
A complete line-up including deluxe units that offer added energy savings. The incorpora-
tion of wide air-outlet and the “i-see Sensor” enhances airflow distribution control, achiev-
ing an enhanced level of comfort throughout the room. The synergy of higher energy effi-
ciency and more comfortable room environment results in the utmost user satisfaction.
PLA-RP35/50/60/71/100/125/140
35 50 60 71 100 125 140
Deluxe 4-way
Cassette
Standard 4-way
Cassette
N Line-up N Indoor/Outdoor Unit Combinations
Power Inverter
Standard Inverter
Fixed-speed
N Energy Efficiency Comparison
New Heat Exchanger Design
Heat exchanger fine size and pitch have been
changed, raising energy efficiency.
Pre-grooved Piping
High-performance pre-grooved piping is utilized,
increasing the heat exchange area.
N Key Technologies for Higher Energy
Efficiency
N Corner Panel Only (Option)
PLA-RP71 BA2
PLA-RP100 BA3 PLA-RP125 BA2
PLA-RP
35BA
PLA-RP
50BA
PLA-RP
60BA
PLA-RP
140BA2
NEW
NEW
PLA-RP71BA
PLA-RP100BA PLA-RP125BA
Model
Series
=Smudge spots on the ceiling may form where the airflow is not evenly distributed.
[Airflow Distribution]
PLA-RP125BA(2)
Flow angle, cooling at 20°C (ceiling height 3.2m)
(m/s)
Floor distribution (m)
Height (m)
5 43210
0
1
2
3
3.2
1.0 2.0
3.0 4.0 5.0
Horizontal
Airflow
A more
horizontal airflow
is achieved using
the new mode.
3.2
m
3.6
m
4.0
m
4.5
m
4.5
m
4.5
m
2.4
m
3.0
m
3.3
m
3.5
m
3.5
m
3.5
m
High-ceiling
setting
Standard
setting
High-ceiling
setting
2.7
m
3.0
m
3.3
m
2.5
m
2.7
m
3.0
m
Low-ceiling
setting
Low-ceiling
setting
Standard
setting
PLA-RP35–71BA PLA-RP100-140BA
4-Way
3-Way
2-Way
NAirflow Range
Model
Airflow
pattern
Downward Downward Downward
Indoor Unit
Indoor Unit
Temperature gap
Uneven temperature distribution
Horizontal Airflow Wave Airflow
Temperature distribution comparison approxi-
mately 20min after turning on a PLA-RP71BA
4-Way ceiling cassette. The measurement point
for comparison is a plane 1.2m above the floor.
Thermograph of Wave Control Effect
Temperature gap is minimized.
Warm air is supplied throughout the room,
minimizing uneven temperature distribution.
3.2m
=
2.7m
=
4.5m
=
=PLA-RP100-140BA
=Wave Airflow is possible only when using the heating mode
4-way airflow with
high-ceiling setting
4-way airflow with
standard setting
4-way airflow with
low-ceiling setting
Airflow direction at
each vane can be set
using the wired remote
controller.
Fixed
Adjustable
Horizontal
Downward
* Optional shuffle placement is required
for 2- and 3-way patterns.
The combination of individual vane setting,
which enables the optimal outlet setting for
each room layout, and the wide airflow function
works to ensure even temperature distribution
throughout each room. The result is uniformly
comfortable air conditioning.
Image of multi-directional
air conditioning
72 airflow patterns
Individual Vane
Setting
Wide Airflow
2-, 3-, 4-way airflow
pattern selection
PLP-6BAE
PAC-SA1 ME-E
or
PLA-RP100BA3 PLA-RP100BA
4.18
3.31
Cooling Heating
PUHZ-RP100VKA PUHZ-RP100VHA2
PLA-RP100BA3 PLA-RP100BA
4.61
3.61
PUHZ-RP100VKA PUHZ-RP100VHA2
The i-see Sensor rotates 90° at intervals of
5 sec, accurately measuring the temperature
throughout the room (covering entire floor space).
Ni-see Sensor Operation
90°
rotation
90°
rotation
90°
rotation
5 sec
measurement
5 sec
measurement
5 sec
measurement
5 sec
measurement
Grille Elevation Remote Controller
(comes with the automatic elevation panel)
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automatic
descent down
to 4m
Wired Remote Controller
N i-see Sensor Panel
EER
26
%
UP
COP
28
%
UP
Deluxe 4-way Cassette
Gentle
Strong
Vista de pagina 0
1

Indice de contenidos

Pagina 1 - 72 airflow patterns

51 52New 4-Way Ceiling CassettePreviousmodelPUHZ-P125/140/200/250PUHZ-RP100/125/140/200/250PUH-P125/140PUH-P71/100PU-P125/140PU-P71/100PUHZ-RP60/71Sta

Comentarios a estos manuales