Mitsubishi Electric MSZ-GC22VA Manual de servicio

Busca en linea o descarga Manual de servicio para Acondicionadores de aire del sistema de división Mitsubishi Electric MSZ-GC22VA. Mitsubishi Electric MSZ-GC22VA Service manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················2
3. SPECIFICATION·················································3
4. NOISE CRITERIA CURVES ·······························4
5. OUTLINES AND DIMENSIONS ·························5
6. WIRING DIAGRAM ············································6
7. REFRIGERANT SYSTEM DIAGRAM ················6
8. SERVICE FUNCTIONS ······································7
9. MICROPROCESSOR CONTROL ······················9
10. TROUBLESHOOTING······································14
11. DISASSEMBLY INSTRUCTIONS·····················26
MSZ-GC22VA -
MSZ-GC22VA -
MSZ-GC25VA -
MSZ-GC25VA -
MSZ-GC35VA -
MSZ-GC35VA -
E2
E1
E2
E1
E2
E1
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
Outdoor unit service manual
MUZ-GC·VA Series (OBH469)
MXZ-A·VA Series (OB377)
MXZ-8A140A (OC316)
SERVICE MANUAL
Wireless type
Models
No. OBH468
REVISED EDITION-B
INDOOR UNIT
PARTS CATALOG (OBB468)
Revision B:
has been added.
E2
Please void OBH468 REVISED EDITION-A.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - INDOOR UNIT

CONTENTS1. TECHNICAL CHANGES ····································22. PART NAMES AND FUNCTIONS······················23. SPECIFICATION··················

Pagina 2 - PART NAMES AND FUNCTIONS

101. Coil frost preventionCoil frost prevention is as same as COOL mode. (9-1.1.)2. Low outside temperature operationLow outside temperature operation

Pagina 3 - SPECIFICATION

11(3) PositioningTo confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selectedangle.Confirm

Pagina 4 - NOISE CRITERIA CURVES

12To change the airflow directionWhen to use this function?Use this function if you don’twant the air from the indoorunit to blow directl

Pagina 5 - OUTLINES AND DIMENSIONS

13EMERGENCY OPERATION switch (E.O. SW)Operation mode COOL HEATSet temperature24:24:Fan speed Medium MediumHorizontal vane Auto AutoThe operation mode

Pagina 6 - REFRIGERANT SYSTEM DIAGRAM

1410TROUBLESHOOTING3. Troubleshooting procedure1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate a

Pagina 7 - SERVICE FUNCTIONS

15Outline of the functionThis air conditioner can memorize the abnormal condition which has occurred once.Even though LED indication listed on the tro

Pagina 8 - Indoor electronic

162. Indoor unit failure mode tableNOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (10-4.). 12-time flash2.5

Pagina 9 - MICROPROCESSOR CONTROL

17StartIndoor unit operates.Outdoor unit doesn'toperate.Indoor unit doesn't receive the signal from remote controller.OPERATION INDICATORla

Pagina 10 - 9-1. COOL ( ) OPERATION

18No.1256SymptomOperation indicator lampConditionCorrespondenceUpper lamp flashes.0.5-second ON0.5-second OFFMis-Wiringor serial signalOutdoorpowersys

Pagina 11 - OPERATION INDICATOR

1910-5. Trouble criterion of main partsMSZ-GC22VA MSZ-GC25VA MSZ-GC35VAMeasure the voltage power ON.FigureMeasure the resistance between the terminals

Pagina 12 - STOP

21TECHNICAL CHANGESMSZ-GA22VA -➔ MSZ-GC22VA -MSZ-GA25VA - ➔ MSZ-GC25VA -MSZ-GA35VA - ➔ MSZ-GC35VA -E1E1E1E1E1E11. Indoor model has been changed. PART

Pagina 13

20Check of remote controller and indoor electronic control P.C. board BIndoor unit operates by pressing EMERGENCY OPERATION switch, but does not opera

Pagina 14 - TROUBLESHOOTING

21The unit does not operate with the remote controller.Also, OPERATION INDICATOR lamp does not light up by pressing EMERGENCY OPERATION switch.Check o

Pagina 15

22How to check mis-wiring and serial signal errorDIs there rated voltage in the power supply?Is there any mis-wiring, poor contact, or wire disconnect

Pagina 16

23Check of installation of the horizontal vaneEReplace the indoor electronic control P.C. board.Replace the interlock switch(Fan).Is the stopper of th

Pagina 17

24Electromagnetic noise enters into TV sets or radiosFReplace or repair the antenna.Replace or repair the coaxial cable.NoNoNoYesYesNoNoYesYesYesIs th

Pagina 18

25Room temperature thermistor (RT11)Indoor coil thermistor (RT12, RT13)Temperature (:)Resistance (k")MSZ-GC22VA MSZ-GC25VA MSZ-GC35VA1. Indoor po

Pagina 19

2611DISASSEMBLY INSTRUCTIONS(1) Slide the sleeve and check if there is a locking lever or not.(2) The terminal with this connector has the lock

Pagina 20 - Check of indoor fan motor

273. Remove the indoor power P.C. board, the indoor ter-minal P.C. board, and the electrical box(1) Turn the breaker OFF.(2) Remove the panel (Refer

Pagina 21

OPERATING PROCEDURE PHOTOS4. Removing the vane motor(1) Turn the breaker OFF.(2) Remove the panel (Refer to 1) and the corner box.(3) Remove the indoo

Pagina 22 - Indoor unit does not operate

3SPECIFICATION3FuseHorizontal vane motorVaristorTerminal block(F11)(MV)(NR11)(TB)T3.15AL 250V12V DCS10K320E3K1(ERZV14D471)3PSpecifications and rating

Pagina 23

44NOISE CRITERIA CURVESMSZ-GC22VAMSZ-GC25VAINDOOR UNITWALLMICROPHONE0.8m1m90807060504030201063 125 250 500 1000 2000 4000 8000NC-60NC-50NC-40NC-30NC-2

Pagina 24

5OUTLINES AND DIMENSIONS5Unit : mm745941.5214235253.518.5320335155 15521540.5254.55959 225 225229553 607 1288100137119PipingInsulation[35 O.DLiquid li

Pagina 25 - Resistance (k")

66WIRING DIAGRAMREFRIGERANT SYSTEM DIAGRAM7MSZ-GC22VAMSZ-GC25VAMSZ-GC35VARefrigerant flow in coolingRefrigerant flow in heatingIndoorheatexchangerFlar

Pagina 26 - Locking lever

7SERVICE FUNCTIONS88-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATIONA maximum of 4 indoor units with wireless remote controllers can be used in a

Pagina 27 - OPERATING PROCEDURE PHOTOS

8NOTE :• The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with theremote controller.• If main power

Pagina 28

9MICROPROCESSOR CONTROL9Once the operation mode is set, the same operation mode can be repeated by simply turning OPERATE/STOP(ON/OFF) button ON.Indoo

Comentarios a estos manuales

Sin comentarios