INSTALLATION MANUAL
FOR INSTALLER
CONTENTS
1. BEFORE INSTALLATION ..............................................................................2
2. OUTDOOR UNIT INSTALLATION .................................................................5
3. FLARING WORK AND PIPE CONNECTION.................................................7
4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN...........................8
Split-type Air-Conditioner
MXZ-3A30NA
MXZ-4A36NA
English
• Refer to the installation manual of each indoor unit for indoor unit in-
stallation.
ATTENTION
This manual mentions how to install only the outdoor unit (MXZ-3A30NA, MXZ-
4A36NA). As for the way of installation for indoor unit, please refer to the installa-
tion manual being attached each indoor unit.
The installation manual details the suggested installation method.
Any structural alterations necessary for installation must comply with local build-
ing code requirements.
Español
Français
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Split-type Air-Conditioner

INSTALLATION MANUALFOR INSTALLERCONTENTS1. BEFORE INSTALLATION ...22. OUTDO

Pagina 4 - 1-6. INSTALLATION DIAGRAM

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANJG79A073H02

Pagina 5 - 2. OUTDOOR UNIT INSTALLATION

21. BEFORE INSTALLATION1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” b

Pagina 6

32.Front (blowing) side openAs long as space like the oneVKRZQLQWKH¿JXUHFDQEHmaintained, it does not mat-ter if there are obstacles inthree dire

Pagina 7 - 3-3. INSULATION AND TAPING

41-6. INSTALLATION DIAGRAM8QLWVVKRXOGEHLQVWDOOHGE\OLFHQVHGFRQWUDFWRUDFFRUGLQJWRORFDOFRGHUHTXLUHPHQWV$IWHUWKHOHDNWHVWDSSO\LQVXODW-LQJ

Pagina 8 - 4-2. GAS CHARGE

52. OUTDOOR UNIT INSTALLATION2-1. INSTALLING THE UNIT %HVXUHWR¿[WKHXQLW¶VOHJVZLWKEROWVZKHQLQVWDOOLQJLW %HVXUHWRLQVWDOOWKHXQLW¿UP

Pagina 9 - 4-3. TEST RUN

6Remark:* A disconnect switch should be required. Check the local code.** Use a ring tongue terminal in order to connect a ground wire to terminal.

Pagina 10

7Fig. 1 Fig. 2Fig. 3 Fig. 4Fig. 5 Fig. 63. FLARING WORK AND PIPE CONNECTION3-1. FLARING WORKPipe diameter>PPLQFK@NutPP$>PPLQFK@ Tighten

Pagina 11

84-2. GAS CHARGEPerform gas charge to unit. &RQQHFWJDVF\OLQGHUWRWKHVHUYLFHSRUWRIVWRSYDOYH 3HUIRUP DLU SXUJH RI WKH SLSH RU K

Pagina 12 - JG79A073H02

9Procedure3UHVVWKHSLSLQJZLULQJFRUUHFWLRQVZLWFK6:PLQXWHRUPRUHDIWHUWXUQLQJRQWKHSRZHUVXSSO\• Correction completes in 10 to 15 minu