OUTLINES AND DIMENSIONS
OUTDOOR UNITS series
OUTDOOR
UNIT
30
35
155
90
198
40
515
299
66
34
51
330
360
850
430
500
80
121
840
Open as a rule
500mm or more if
the front and both
sides are open
100mm or more
200mm or more if
there are obstacles
to both sides
Open as a rule
500mm or more if the back,
both sides and top are open
350mm or more
100mm or more
Service panel
Gas refrigerant
pipe joint
Refrigerant pipe(flared)
:12.7·····(SUZ-KA50VA)
:15.88···(SUZ-KA60/KA71VA)
Liquid refrigerant
pipe joint
Refrigerant pipe(flared)
:6.35·····(SUZ-KA50/KA60VA)
:9.52·····(SUZ-KA71VA)
REQUIRED SPACE
OUTDOOR UNIT
SUZ-KA50VA Unit: mm
SUZ-KA60VA
SUZ-KA71VA
Vista de pagina 0
1 2 3 4 5 6 ... 36 37

Indice de contenidos

Pagina 1 - SUZ-KA71VA

B-87OUTLINES AND DIMENSIONSOUTDOOR UNITS seriesOUTDOORUNIT3035155901984051529966345133036085043050080121840Open as a rule500mm or more ifthe front a

Pagina 2 - MODELS WIRING DIAGRAM

B-111CAPACITY CORRECTION RATIO CURVE PIPING LENGTHOUTDOOR UNITS seriesOUTDOORUNITB.3.9 CAPACITY CORRECTION RATIO CURVE PIPING LENGTH85%86%87%88%89%90%

Pagina 3

B-113INSTALLATION PROCEDUREOUTDOOR UNITS seriesOUTDOORUNITAir outlet285 mm344.5 mmAir out40330Air in662995153451Air in3605003. Installation diagram4.1

Pagina 4 - PERFORMANCE CURVES

OUTDOOR UNITB-114INSTALLATION PROCEDURES seriesOUTDOORUNIT5.2. Flaring work• Main cause of gas leakage is defect in flaring work.Carry out correct fla

Pagina 5 - B.3.5 NOISE CRITERIA CURVES

OUTDOOR UNITB-116INSTALLATION PROCEDURES seriesOUTDOORUNITS3S3S2S1S2S1L N21LN• Perform wiring as shown in the diagram to the lower left. (Procure the

Pagina 6 - B.3.6 ACTUATOR CONTROL

B-117INSTALLATION PROCEDUREOUTDOOR UNITS seriesOUTDOORUNIT7. Maintenance7.1. Gas charge (Fig. 7-1)1. Connect gas cylinder to the service port of stop

Pagina 7 - B.3.7 TROUBLESHOOTING

C-1M seriesM series ModelsCOMBINATION OF SINGLE SPILIT TYPETypeModel NameIndoor unit Outdoor unitWall- MountedFixed-SpeedCooling onlyMSC-GE20VB E1 M

Pagina 8 - S series

FLOOR-STANDING Inverter Heat PumpM seriesC-236SPECIFICATIONSFLOOR-STANDINGC.2.1.1 Inverter Heat PumpC.2.1 SPECIFICATIONSModel Name Indoor Unit MFZ-K

Pagina 9 - 3.Specification

FLOOR-STANDING Indoor Unit/Outdoor unitM seriesOUTLINE S AND DIMENSIONSFLOOR-STANDINGC-237C.2.2.1 Indoor UnitC.2.2 OUTLINES AND DIMENSIONSWireless r

Pagina 10 - OUTDOOR UNITS series

FLOOR-STANDING Outdoor Unit M seriesOUTLINE S AND DIMENSIONSFLOOR-STANDINGC-238Unit: mm3035155901984051529966345133036085043050080121840Open as a ru

Pagina 11 - 3. Installation diagram

FLOOR-STANDING Indoor UnitM seriesWIRING DIAGRAMFLOOR-STANDINGC-239MFZ-KA25VAMFZ-KA35VAMFZ-KA50VAC.2.3.1 Indoor UnitC.2.3 WIRING DIAGRAMINDOOR UNIT

Pagina 12 - 5. Refrigerant piping work

B-89WIRING DIAGRAMOUTDOOR UNITS seriesOUTDOORUNITPOWER SUPPLY~/N 230V 50HzCIRCUITBREAKERTO INDOORUNITCONNECTING230V~12-24VS3S1S2TB2BRNBLUREDLNGRN/YLWT

Pagina 13 - 6. Electrical work

FLOOR-STANDING Outdoor Unit M seriesWIRING DIAGRAMFLOOR-STANDINGC-242SUZ-KA50VAR2.THOUTDOOR UNITPOWER SUPPLY~/N 230V 50HzCIRCUITBREAKERTO INDOORUNITCO

Pagina 14 - 7. Maintenance

FLOOR-STANDING Inverter Heat Pump M seriesREFRIGERANT SYSTEM DIAGRAMFLOOR-STANDINGC-244Unit: mmINDOOR UNITMFZ-KA50VAOUTDOOR UNITSUZ-KA50VAR2.TH Outdo

Pagina 15 - M series

FLOOR-STANDING Inverter Heat PumpM seriesPERFORMANCE CURVESFLOOR-STANDINGC-245C.2.5 PERFORMANCE CURVESThe standard data contained in these specificat

Pagina 16 - C.2.1 SPECIFICATIONS

FLOOR-STANDING Inverter Heat PumpM seriesPERFORMANCE CURVESFLOOR-STANDINGC-246C.2.5.1 Inverter Heat PumpCAPACITY AND THE INPUT CURVESCooling capacity

Pagina 17 - REQUIRED SPACE

FLOOR-STANDING Inverter Heat PumpM seriesPERFORMANCE CURVESFLOOR-STANDINGC-247OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT <How to operate fixed

Pagina 18 - SUZ-KA50VAR2.TH

FLOOR-STANDING Inverter Heat PumpM seriesPERFORMANCE CURVESFLOOR-STANDINGC-248 Air flow: High speed Operational frequency : 56.5 Hz (SUZ-KA25VA(H)R1.

Pagina 19 - C.2.3 WIRING DIAGRAM

FLOOR-STANDING Inverter Heat PumpM seriesPERFORMANCE DATAFLOOR-STANDINGC-253INDOOR INDOOR21OUTDOOR DB(°C)25 27 30WB(°C)Q SHC SHF Q SHC SHF Q SHC SH

Pagina 20

FLOOR-STANDING Inverter Heat Pump M seriesPERFORMANCE DATAFLOOR-STANDINGC-25435 40 46OUTDOOR DB(°C)INDOOR INDOORDB (°C) WB (°C)Q SHC SHF INPUT Q SH

Pagina 21 - MFZ-KA50VA

FLOOR-STANDING Inverter Heat PumpM seriesPERFORMANCE DATAFLOOR-STANDINGC-255INDOOR-10Q INPUT-5Q INPUT0Q INPUT5Q INPUT10Q INPUT15Q INPUT20Q INPUT152126

Pagina 22 - C.2.5 PERFORMANCE CURVES

FLOOR-STANDING Inverter Heat Pump M seriesNOISE CRITERIA CURVESFLOOR-STANDINGC-256C.2.7.1 Inverter Heat PumpC.2.7 NOISE CRITERIA CURVES9080706050403

Pagina 23 - CAPACITY AND THE INPUT CURVES

B-93REFRIGERANT SYSTEM DIAGRAMOUTDOOR UNITS seriesOUTDOORUNITUnit: mmSUZ-KA50VAOutdoorheatexchangerFlared connectionDefrostthermistorRT61Dischargetemp

Pagina 24

FLOOR-STANDING Inverter Heat PumpM seriesTROUBLESHOOTINGFLOOR-STANDINGC-257C.2.8 TROUBLESHOOTINGFailure mode recall functionMFZ-KA25VA MFZ-KA35VA M

Pagina 25 - HEATING operation

FLOOR-STANDING Inverter Heat Pump M seriesTROUBLESHOOTINGFLOOR-STANDINGC-2582. Indoor unit failure mode tableNOTE: Blinking patterns of this mode diff

Pagina 26 - PERFORMANCE DATA

FLOOR-STANDING Inverter Heat PumpM seriesTROUBLESHOOTINGFLOOR-STANDINGC-259NOTE: When the indoor unit has started operation and the above failures are

Pagina 27

FLOOR-STANDING Inverter Heat Pump M seriesTROUBLESHOOTINGFLOOR-STANDINGC-260MFZ-KA25VA MFZ-KA35VA MFZ-KA50VAOPERATION INDICATORNot lightedBlinkingLi

Pagina 28

FLOOR-STANDING Inverter Heat PumpM seriesINSTALLATION PROCEDUREFLOOR-STANDINGC-261SPECIFICATIONS*1 Connect to the power switch which has a gap of 3 mm

Pagina 29 - C.2.7 NOISE CRITERIA CURVES

FLOOR-STANDING MFZ-KA• VA SeriesM seriesCENTER OF GRAVITY POSITIONFLOOR-STANDINGC-273C.2.11 CENTER OF GRAVITY POSITION Unit: mmIndoor model A B C a

Pagina 30 - C.2.8 TROUBLESHOOTING

E-2Optional Parts List <Indoor>Option partIndoor unitFilteri-see sensor corner panelShutter plateMulti-functional casementDuct ange for fresh a

Pagina 31 - STANDING

E-4Optional Parts List <Outdoor>Option partOutdoor unitDistribution pipe Joint pipeFilter dryer for liquid pipeFor twin use (50:50)For triple u

Pagina 32 - Troubleshooting Check Table

B-97PERFORMANCE CURVESOUTDOOR UNITS seriesOUTDOORUNITCooling capacity0.60.70.80.91.01.11.21.31.41.5-10 -5 0 5 10 15 20 25 30 35 40 45Outdoor intake ai

Pagina 33 - OPERATION INDICATOR

B-99NOISE CRITERIA CURVESOUTDOOR UNITS seriesOUTDOORUNITB.3.5 NOISE CRITERIA CURVES90807060504030201063 125 250 500 1000 2000 4000 8000NC-60NC-50NC-40

Pagina 34 - C.2.9 INSTALLATION PROCEDURE

OUTDOOR UNITB-100ACTUATOR CONTROLS seriesOUTDOORUNITDischarge temperature thermistorIndoor pipe temperature thermistorDefrost thermistorFin temperatur

Pagina 35 - VA SeriesM series

B-101TROUBLESHOOTINGOUTDOOR UNITS seriesOUTDOORUNITB.3.7 TROUBLESHOOTINGSUZ-KA25VA SUZ-KA35VASUZ-KA50VA SUZ-KA60VA SUZ-KA71VA1. Cautions on trouble

Pagina 36

OUTDOOR UNITB-104TROUBLESHOOTINGS seriesOUTDOORUNITAbnormal point (Failure mode/protection) LED indication(Outdoor P.C. board) Condition Correspondenc

Pagina 37 - (25:25:25:25)

B-109EARTHQUAKE-PROOF STRENGTH ANALYSISOUTDOOR UNITS seriesOUTDOORUNITEarthquake-proof strength analysis <Anchor bolt>1.Type:2.Model name: SUZ-K